In order to meet the request of current real test, the technology team of research on IT-Tests.com HP HP0-S33 exam materials is always update the questions and answers in time. We always accept feedbacks from users, and take many of the good recommendations, resulting in a perfect IT-Tests.com HP HP0-S33 exam materials. This allows IT-Tests.com to always have the materials of highest quality.
IT-Tests.com have a strong It expert team to constantly provide you with an effective training resource. They continue to use their rich experience and knowledge to study the real exam questions of the past few years. Finally IT-Tests's targeted practice questions and answers have advent, which will give a great help to a lot of people participating in the IT certification exams. You can free download part of IT-Tests's simulation test questions and answers about HP certification HP0-S33 exam as a try. Through the proof of many IT professionals who have use IT-Tests's products, IT-Tests.com is very reliable for you. Generally, if you use IT-Tests's targeted review questions, you can 100% pass HP certification HP0-S33 exam. Please Add IT-Tests.com to your shopping cart now! Maybe the next successful people in the IT industry is you.
As a member of the people working in the IT industry, do you have a headache for passing some IT certification exams? Generally, IT certification exams are used to test the examinee's related IT professional knowledge and experience and it is not easy pass these exams. For the examinees who are the first time to participate IT certification exam, choosing a good pertinent training program is very necessary. IT-Tests.com can offer a specific training program for many examinees participating in IT certification exams. Our training program includes simulation test before the formal examination, specific training course and the current exam which has 95% similarity with the real exam. Please add IT-Tests.com to you shopping car quickly.
Now passing HP certification HP0-S33 exam is not easy, so choosing a good training tool is a guarantee of success. IT-Tests.com will be the first time to provide you with exam information and exam practice questions and answers to let you be fully prepared to ensure 100% to pass HP certification HP0-S33 exam. IT-Tests.com can not only allow you for the first time to participate in the HP certification HP0-S33 exam to pass it successfully, but also help you save a lot of valuable time.
We will free provide you part of the exercises of HP certification HP0-S33 exam on the Internet to let you try to test our product's quality. After your trail you will find IT-Tests's exercises is the most comprehensive one and is what you want to.
We all know that in the fiercely competitive IT industry, having some IT authentication certificates is very necessary. IT authentication certificate is a best proof for your IT professional knowledge and experience. HP HP0-S33 is a very important certification exam in the IT industry and passing HP certification HP0-S33 exam is very difficult. But in order to let the job position to improve spending some money to choose a good training institution to help you pass the exam is worthful. IT-Tests's latest training material about HP certification HP0-S33 exam have 95% similarity with the real test. If you use IT-Tests'straining program, you can 100% pass the exam. If you fail the exam, we will give a full refund to you.
Exam Code: HP0-S33
Exam Name: HP (Advanced Integration and Management of HP Server Solutions)
Free One year updates to match real exam scenarios, 100% pass and refund Warranty.
Total Q&A: 79 Questions and Answers
Last Update: 2014-03-18
HP0-S33 (Advanced Integration and Management of HP Server Solutions) Free Demo Download: http://www.it-tests.com/HP0-S33.html
NO.1 What can you configure with the BladeSystem Insight Display on a c7000 enclosure? (Select
three)
A. Rack name
B. Power mode
C. Number of fans installed
D. OA1 IP address
E. Blade name
F. Midplane serial number
Answer: A,B,D
HP exam simulations HP0-S33 HP0-S33 HP0-S33 test answers
Reference:
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00698534 /c00698534.pdf(page 13)
NO.2 You are experiencing problems with a Virtual Connect domain and want to verify the domain
status. Which tool can you use to perform a domain health check?
A. Service Pack for ProLiant
B. Active System Health Log
C. Virtual Connect Active Health
D. Virtual Connect Support Utility
Answer: D
HP test answers HP0-S33 pdf HP0-S33
Reference:
http://bizsupport.austin.hp.com/bc/docs/support/SupportManual/c01566977 /c01566977.pdf (page
17, see step 2)
Step 2-Run a health check on the Virtual Connect domain
1. From a local system with VCSU installed, execute the following command:
vcutil -a healthcheck -i <Primary OA IP> -u <OA Admin account> -p <OA password>
NO.3 Which host is selected as a master host in the VMware HA cluster?
A. The host with access to the greatest number of the datastores
B. The host with the redundancy configured for management network
C. The host with the greatest number of virtual machines configured with fault tolerance
D. The host with the greatest CPU and memory capacity
Answer: A
HP HP0-S33 HP0-S33 exam HP0-S33 original questions HP0-S33 test
Explanation:
http://pubs.vmware.com/vsphere50/index.jsp?topic=%2Fcom.vmware.vsphere.avail.doc_50%2FGU
IDB9ACCE9B-A14D-4B2F87EF-4B0A67ABDF58.html
When you add a host to a vSphere HA cluster, an agent is uploaded to the host and configured to
communicate with other agents in the cluster. Each host in the cluster functions as a master host or
a slave host. When vSphere HA is enabled for a cluster, all active hosts (those not in standby or
maintenance mode, or not disconnected) participate in an election to choose the cluster's master
host. The host that mounts the greatest number of datastores has an advantage in the election.
Only one master host exists per cluster and all other hosts are slave hosts. If the master host fails, is
shut down, or is removed from the cluster a new election is held.
NO.4 To protect virtual running on multiple ESXi 5.0 hosts, a customer decides to configure a High
Availability cluster. What are the requirements for this type of cluster?
A. The management network must be configured with the Fast Tolerant option enabled.
B. Enhanced VMotion compatibility mode and Storage DRS must be enabled on the cluster level.
C. Virtual machine must be stored on the datastore available from each member of the cluster.
D. The cluster must be configured using Host Profiles.
Answer: C
HP HP0-S33 answers real questions HP0-S33 questions HP0-S33 braindump HP0-S33 exam prep
Explanation:
Requirements for a VMware HA Cluster Review this list before setting up a VMware HA cluster. For
more information, follow the appropriate cross reference or see Creating a VMware HA Cluster.
All hosts must be licensed for VMware HA. You need at least two hosts in the cluster. All hosts need
a unique host name. All hosts need to be configured with static IP addresses. If you are using DHCP ,
you must ensure that the address for each host persists across reboots. All hosts must have access
to the same management networks. There must be at least one management network in common
among all hosts and best practice is to have at least two. Management networks differ depending
on the version of host you are using. ESX hosts - service console network. ESXi hosts earlier than
version 4.0 - VMkernel network. ESXi hosts version 4.0 and later - VMkernel network with the
Management Network checkbox enabled.
See Networking Best Practices. To ensure that any virtual machine can run on any host in the cluster,
all hosts should have access to the same virtual machine networks and datastores. Similarly, virtual
machines must be located on shared, not local, storage otherwise they cannot be failed over in the
case of a host failure. For VM Monitoring to work, VMware tools must be installed. See VM and
Application Monitoring. All hosts in a VMware HA cluster must have DNS configured so that the
short host name (without the domain suffix) of any host in the cluster can be resolved to the
appropriate IP address from any other host in the cluster. Otherwise, the Configuring HA task could
fail. If you add the host using the IP address, also enable reverse DNS lookup (the IP address should
be resolvable to the short host name).
NO.5 A customer needs a direct attached based storage for a BladeSystem and wants a solution that
enables low cost zoned or shared storage.
Which type of HP external storage meets the customer requirements?
A. Direct Connect SAS storage
B. Infiniband
C. Fibre Channel over Ethernet
D. Serial Attached SCSi
Answer: A
HP certification training HP0-S33 pdf HP0-S33 pdf HP0-S33 certification HP0-S33
Explanation:
http://h18006.www1.hp.com/products/storageworks/sas_solution/index.html (Overview, first para)
With the direct connect SAS storage for HP BladeSystem, HP extends and redefines direct-attached
storage for BladeSystem servers. Now you can build local server storage on the fly with zoned
storage, or enable low cost shared storage within the rack
NO.6 When developing an implementation Plan, what does the acceptance criteria establish?
A. Exit criteria for transactioning the system into production
B. Minimum level of performance required for plan continuation
C. Authorization to continue toward funding of the project
D. Authorization to start or implement the project plan
Answer: C
HP test questions HP0-S33 certification HP0-S33 HP0-S33 braindump HP0-S33 demo
NO.7 You want to create a service template using I/O Designer that will be deployed to the Hyper-V
host. Currently, only VMware templates have been used in this environment.
How must you prepare a virtual machine template to use for this template?
A. Use the Insight Control Server migration functionality to migrate the VM from VMware to
Hyper-V and then use the vCenter server to prepare the template recognized by I/O.
B. You can use VMware templates for Hyper-V deployment since I/O is virtualization layer
independent.
C. Use the I/O converter tool to convert the VMware template to change it to the correct format.
D. Create a virtual machine template using Insight Control virtual machine management
functionality.
Answer: D
HP test answers HP0-S33 test HP0-S33 HP0-S33 test HP0-S33 pdf
NO.8 A customer is running HP SIM in a headquarters that has three branch offices with multiple
server blades managed by the HP SIM in a central location. Version Control Repository Manager is
configured in all branch offices, but all deployment tasks should be performed from the central
location. What must you configure first?
A. all remote VCRMs properly licensed
B. Secure tunnel between headquarters and the branch offices
C. Additional CMS server in the brach offices that will not perform any management function and
will work as a federated CMS and give access to the local VCRM
D. Trust relationship between HP SIM and the machines running VCRM in remote locations
Answer: D
HP HP0-S33 exam dumps HP0-S33 HP0-S33 study guide
NO.9 A customer complained of slow performance on an HP ProLiant server. You upgraded to faster
processes and added memory to the server. What should you create after you change the server
hardware configuration?
A. New performance baseline
B. Insight Diagnostics report
C. CPU Stress report
D. Memory Validation report
Answer: A
HP HP0-S33 original questions HP0-S33
NO.10 Which Windows performance counter can be used to check for a Smart Array disk bottleneck
problem?
A. Logical Disk: Average Disk Queue Length
B. Physical Disk: Average Disk Queue length
C. Logical Disk: Average Disk Write Queue Length
D. Physical Disk: Average Disk Write Queue Length
Answer: B
HP braindump HP0-S33 HP0-S33 HP0-S33
IT-Tests.com offer the latest 70-341 Questions & Answers and high-quality CUR-051 PDF Practice Test. Our 000-283 VCE testing engine and 1Z0-061 study guide can help you pass the real exam. High-quality LOT-408 Real Exam Questions can 100% guarantee you pass the exam faster and easier. Pass the exam to obtain certification is so simple.
Article Link: http://www.it-tests.com/HP0-S33.html
没有评论:
发表评论